For 4 pipe with 4 nominal thickness insulation f 77.
Calcium silicate pipe insulation weight per foot.
To simplify heat loss calculations pipe heat loss is based on the heat loss per linear foot rather than the entire area of any given length.
Thermo 12 gold is composed of hydrous calcium silicate and is made with xox corrosion inhibitor a proprietary formula and process that inhibits corrosion to the outside surfaces of pipe and.
7 2 1 fit and closure when fitted to the appropriate size pipe by banding on 9 in.
Stanwood pr newswire effective immediately thermal pipe shields tps a privately held mechanical insulation supply company with three generations of industry engagement dating.
Calcium silicate is used to insulate high temperature pipes and equipment and for fire endurance applications.
The listed thicknesses and weights of combination covering are the sums of the inner layer of diatomaceous earth at 21 ibs cu.
Preformed block preformed pipe and board.
Foot and the outer layer at 11 ibs cubic foot.
April 7 2018.
Thermo 1200 is the only north american.
7 2 pipe insulation the following additional dimensional tolerances apply only to calcium silicate pipe insulation sup plied as half sections.
Nominal size pounds per linear ft nominal size pounds per linear ft nominal size pounds per linear ft nominal size pounds per linear ft x1 1 2 x2 5 6x3 11 15x3 20.
Thermo 12 gold is a pre formed high temperature abuse resistant pipe and block insulation it has exceptional structural strength and can be used on operating systems that reach 1200 f 650 c.
Pipe insulation support saddles the span load is determined by the total weight of the pipe filled with water covered with insulation and metal jacketing per linear foot multiplied by because it s a hydrous mass insulation using calcium silicate on cold applications isn t recommended.
Calcium silicate pipe block insulation linear foot chart the following table shows the weight per linear foot of thermo 1200 for the purpose of estimating the load on pipe supports.
Today s calcium silicate manufactured in north america is noted for its high compressive strength corrosion inhibiting properties and high temperature structural integrity.
Also for pipe insulation the outer area of q m1c1 m 2 c2 mncn δt 3 412 where n is the number of materials each material s weight visit document.
Then multiply f by the density of the insulation in pounds per cubic foot.
Insulation weights are based on 85 magnesia and hydrous calcium silicate at 11 ibs cu.
Calculating heat loss by mark crombie chromalox posted.
Insulation weights include allowances for wire ce.
Announcing tpsx 12 water resistant calcium silicate industrial insulation from thermal pipe shields.
It is manufactured and sold in three different forms.
Wednesday march 7 2018 8 13 am pst.
To determine the weight per foot of any piping insulation use the pipe size and nominal insulation thickness to find the insulation weight factor f in the chart shown below.